CAN/CSA C22.2 NO. 60601-2-43:24 PDF

CAN/CSA C22.2 NO. 60601-2-43:24 PDF

Name:
CAN/CSA C22.2 NO. 60601-2-43:24 PDF

Published Date:
01/29/2024

Status:
Active

Description:

Medical electrical equipment - Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures (Adopted IEC 60601-2-43:2022, third edition, 2022-12, with Canadian deviations)

Publisher:
Canadian Standards Association / National Standard of Canada

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$153
Need Help?

CSA Preface 

This is the third edition of CSA C22.2 No. 60601-2-43, Medical electrical equipment — Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures , which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60601-2-43 (third edition, 2022-12). It supersedes the previous edition, published in 2011 as CAN/CSA-C22.2 No. 60601-2-43 (adopted IEC 60601-2-43:2010). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as "CSA C22.2 No. 60601-2-43" throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60601-1:14, Medical electrical equipment — Part 1: General requirements for basic safety and essential performance (adopted IEC 60601-1:2005, including Amendment 1:2012 and Amendment 2:2020, with Canadian deviations). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Consumer and Commercial Products, under the jurisdiction of the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. Due to the medical content of this Standard, it was also approved by the CSA Technical Committee on Application of Electricity in Health Care, under the jurisdiction of the CSA Strategic Steering Committee on Health and Well-being. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. 

Scope Replacement: This document applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of both FIXED and MOBILE X-RAY EQUIPMENT declared by the MANUFACTURER to be suitable for RADIOSCOPICALLY GUIDED INTERVENTIONAL PROCEDURES, hereafter referred to as INTERVENTIONAL X-RAY EQUIPMENT. Its scope excludes, in particular: - equipment for RADIOTHERAPY; - equipment for COMPUTED TOMOGRAPHY; - ACCESSORIES intended to be introduced into the PATIENT; - mammographic X-RAY EQUIPMENT; - dental X-RAY EQUIPMENT. NOTE 1 Examples of RADIOSCOPICALLY GUIDED INTERVENTIONAL PROCEDURES, for which the use of INTERVENTIONAL X-RAY EQUIPMENT complying with this document is recommended, are given in Annex AA. NOTE 2 Specific requirements for magnetic navigation devices, and for the use of INTERVENTIONAL X-RAY EQUIPMENT in an operating room environment were not considered in this document; therefore, no specific requirements have been developed for these devices or uses. In any case, such devices or uses remain under the general clause requirements. NOTE 3 INTERVENTIONAL X-RAY EQUIPMENT, when used for cone-beam CT mode, is covered by this document and not by IEC 60601-2-44 [1]1. No additional requirements for operation in cone-beam CT mode were identified for this document (see also Note 5 in 203.6.4.5). INTERVENTIONAL X-RAY EQUIPMENT declared by the MANUFACTURER to be suitable for RADIOSCOPICALLY GUIDED INTERVENTIONAL PROCEDURES, which does not include a PATIENT SUPPORT as part of the system, is exempt from the PATIENT SUPPORT provisions of this document. If a clause or subclause is specifically intended to be applicable to INTERVENTIONAL X-RAY EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to INTERVENTIONAL X-RAY EQUIPMENT and to ME SYSTEMS, as relevant. IEC 60601-2-54 applies only with regards to the cited subclauses; non-cited subclauses of IEC 60601-2-54 do not apply. 


Edition : 3rd
File Size : 1 file , 4.2 MB
ISBN(s) : 9781488349454
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 154
Product Code(s) : 2431164, 2431164
Published : 01/29/2024

History

CAN/CSA C22.2 NO. 60601-2-43:24
Published Date: 01/29/2024
Medical electrical equipment - Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures (Adopted IEC 60601-2-43:2022, third edition, 2022-12, with Canadian deviations)
$153
CAN/CSA C22.2 NO. 60601-2-43:11+A1:19+A2:21(R2021)
Published Date: 02/02/2022
Medical electrical equipment - Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures (IEC 60601-2-43:2010+A1:2017+A2:2019, MOD)
$221.7
CAN/CSA C22.2 NO. 60601-2-43:11 (R2021) + A1:2019 (CONSOLIDATED)
Published Date: 03/30/2012
Medical electrical equipment - Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures (Adopted IEC 60601-2-43:2010, second edition, 2010-03), Includes Update (2019)
$126.3
CAN/CSA C22.2 NO. 60601-2-43-03 (R2007)
Published Date: 06/01/2003
Medical Electrical Equipment - Part 2-43: Particular Requirements for the Safety of X-Ray Equipment for Interventional Procedures (Adopted IEC 60601-2-43:2000, first edition, 2000-06)
$51.3

Related products

CAN/CSA C22.2 NO. 60601-2-50:23
Published Date: 03/27/2023
Medical electrical equipment - Part 2-50: Particular requirements for the basic safety and essential performance of infant phototherapy equipment (Adopted IEC 60601-2-50:2020, third edition, 2020-09)
$95.7
CAN/CSA C22.2 NO. 60601-2-40:17 (R2022)
Published Date: 05/31/2017
Medical electrical equipment - Part 2-40: Particular requirements for the basic safety and essential performance of electromyographs and evoked response equipment (Adopted IEC 60601-2-40:2016, second edition, 2016-08, with Canadian deviations)
$27

Best-Selling Products

ANSI 136.48-2023
Published Date: 12/01/2023
American National Standard For Roadway and Area Lighting Equipment - Wireless Networked Lighting Controllers
$23.4
ANSI A14.2-1972
Published Date: 1972
American National Standard: Safety Requirements for Portable Metal Ladders
$2.4
ANSI A14.2-1990
Published Date: 09/25/1992
American National Standard for Ladders, Portable Metal, Safety Requirements
ANSI A14.2-2000
Published Date: 01/01/2000
American National Standard for Ladders - Portable Metal - Safety Requirements
ANSI A14.2-2017
Published Date: 2017
American National Standard for Ladders - Portable Metal - Safety Requirements
$82.5
ANSI A14.4-2002
Published Date: 01/01/2002
American National Standard Safety Requirements for Job Made Wooden Ladders